CVE-2023-38950
CISA 기관 조치 기한: 2025-06-09
ZKTeco BioTime
Qualys 위협 인텔 · 심각도 4/5 · QID 732606 · CGI
공개 익스플로잇
쉬운 악용
대량 데이터 유출
CISA KEV
A path traversal vulnerability in the iclock API of ZKTeco BioTime v8.5.5 allows unauthenticated attackers to read arbitrary files via supplying a crafted payload. This vulnerability was fixed in version 9.0.120240617.19506 of ZKBioTime.
KEV 필수 조치: Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
타임라인
- NVD 공개
- CISA KEV 등재(실제 악용 확인) 공개 후 655일
- CISA 기관 조치 기한 경과
벡터: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N